1.No need other power supply for auto generating electric system
2.5 seconds instantaneous heating
3.Durable heating
4. Function of mixer: mixer cold water and hot water.
5. Manual installation : Easy and simple to be installed
| Circuit breaker | Cable size | Voltage | Power rating |
| 50A | 10mm2 | 110/127V | 4000/5400W |
| 40A | 6mm2 | 110/127V | 3300/4400W |
| 30A | 4mm2 | 220/230V | 5400W |
| 25A | 4mm2 | 220/230V | 4400W |
| 35A | 6mm2 | 127V | 3850W |
| Frequency | 50/60hz | Out water temperature | 30-60℃ |
| IP class | IP24 | Grounding wire | YES |
| Water flow | 5L/min | Hose and hand shower | YES |
1.The hand shower is attached to the shower head.Place the selector key in the position desired.The water temperature can be controlled through the water value.
2.Depending on the cost of the shower head,you can get a variety of sprays to improve your shower experience.they supply water at a consistent temperature which can be varied depending on user preference.
| Problem | Problem reason | Solution |
| The water is cold | The selection temperature is in
the off position |
Put the selection temperature key
in the hot or warm position |
| No water is flowing through the shower head | The main register is closed or
there is air inside the pipes |
Open the main register and/or the
taps and let the water flow to remove the air. The shower head must be disconnected of the electrical system . |
| The shower head is not heating
properly even with select key in the not position |
The wires do not have the
properly size as specified in the instruction manual. |
Contact a qualified technician. To
check your electrical installation.
|
| Low voltage: The voltage of your
system may be not constant or under the values specified. |
Contact a qualified technician. To
verify your electrical system. If the nominal voltage of your system are under the values specified by your electric supplier (110~/127~or220V~), contact the utility responsible for your electrical supply. |
|
|
Burn of the element |
Wear due to the normal use | Heating element change |
| Inadequate electric installation | Check the voltage and
characteristics from the electric installation, correct them and change the element according indication above. |